The C-TOP+ control unit with AS-i (Actuator Sensor Interface) communication is designed or intended for the optimal automation of INOXPA process valves. This option is available for the entire range of valves supplied with C-TOP+ units (ball valvebutterfly valvesingle and double seat multiway valve, etc.).

Information

C-TOP+ AS-i Cotrol Unit

Information

Funktionsweise

The AS-i interface is a field bus system that allows connecting a network of actuators and sensors (detectors) to a higher level control device (master).

An AS-i network comprises the following elements:
A power supply, one or several master (or control) modules, bus cable (preformed cable), an IDC connector, an IDC connector to C-TOP+ connector connection cable, and the C-TOP+ prepared for AS-i (special card for AS-i with connector).

The AS-i field bus obtains the required voltage from a power supply. The sensors and solenoid valves connected to the field bus are controlled by the master module.
Every master sends the information to the PLC and is able to control up to 62 slave units (62 C-TOP+ AS-i units).

The interconnection is made with a preformed cable. The preformed cable is used both for the transmission of information and as a power supply for the solenoid valves and detectors. The C-TOP AS-i head must always be used in conjunction with magnetoresistive detectors.

The C-TOP+ AS-i also incorporates three signalling LEDs which continuously indicate the status of the valve, and one flashing red LED to alert in case of signal loss.

Aufbau und Kenndaten

The C-TOP+ AS-i is characterised by its modular simple and robust design which guarantees maximum flexibility during installation. Due to its enormously reduced wiring requirements, it facilitates the installation and commissioning of the system. Moreover, it reduces the commissioning time and potential installation errors.

Depending on the version, the head can have up to three solenoid valves 3/2 (NC) and three sensors. If necessary, an additional external sensor can be connected. The sensors are magnetoresistive, with contactless activation by means of a magnet connected to the control shaft. The C-TOP+ AS-i heads are configured according to each customer's requirements.

Solenoid valve configuration
• Single-acting - 1 solenoid valve
• Double-acting - 2 solenoid valves
• Mixproof valve - 3 solenoid valves

Detector configuration
• 1 position (valve open or closed) - 1 detector
• 2 positions (valve open and closed) - 2 detectors
• 3 positions (valve open, valve closed, Mixproof seat cleaning) - 3 detectors

Materialien

Cover: Polypropylene
Body: Reinforced polypropylene
Base: Reinforced polypropylene
Seals: EPDM
Screws: Stainless steel

Dokument

Funktionsweise

The AS-i interface is a field bus system that allows connecting a network of actuators and sensors (detectors) to a higher level control device (master).

An AS-i network comprises the following elements:
A power supply, one or several master (or control) modules, bus cable (preformed cable), an IDC connector, an IDC connector to C-TOP+ connector connection cable, and the C-TOP+ prepared for AS-i (special card for AS-i with connector).

The AS-i field bus obtains the required voltage from a power supply. The sensors and solenoid valves connected to the field bus are controlled by the master module.
Every master sends the information to the PLC and is able to control up to 62 slave units (62 C-TOP+ AS-i units).

The interconnection is made with a preformed cable. The preformed cable is used both for the transmission of information and as a power supply for the solenoid valves and detectors. The C-TOP AS-i head must always be used in conjunction with magnetoresistive detectors.

The C-TOP+ AS-i also incorporates three signalling LEDs which continuously indicate the status of the valve, and one flashing red LED to alert in case of signal loss.

Materialien and Optionen

Cover: Polypropylene
Body: Reinforced polypropylene
Base: Reinforced polypropylene
Seals: EPDM
Screws: Stainless steel

Dokument N° FT.C-TOP+ AS-i.1_ES
Titel C-TOP+ with AS-i Communication
Dateityp .pdf
Zusammenfassung El C-TOP+ con comunicación AS-i (Actuator Sensor Interface) está diseñado o pensado para una automatización óptima de las válvulas de proceso de INOXPA.
    Download
  • E-mail
Dokument N° FT.C-TOP+ AS-i.1_EN
Titel C-TOP+ with AS-i Communication
Dateityp .pdf
Zusammenfassung The C-TOP+ control unit with AS-i (Actuator Sensor Interface) communication is designed or intended for the optimal automation of INOXPA process valves.
    Download
  • E-mail
Dokument N° FT.C-TOP+ AS-i.1_FR
Titel C-TOP+ avec Bus AS-i
Dateityp .pdf
Zusammenfassung Le C-TOP+ avec bus AS-i (Actuator Sensor Interface) est conçu ou pensé pour optimiser l'automatisation des vannes de process d'INOXPA.
    Download
  • E-mail
Dokument N° FT.C-TOP+ AS-i.1_RU
Titel C-TOP+ с Коммуникацией AS-i
Dateityp .pdf
Zusammenfassung Контрольное устройство C-TOP+ с коммуникацией AS-i (Actuator Sensor Interface) разработано для оптимальной автоматизации поточных клапанов от INOXPA.
    Download
  • E-mail
Dokument N° FT.C-TOP+ AS-i.1_IT
Titel C-TOP+ con Comunicazione AS-i
Dateityp .pdf
Zusammenfassung Il C-TOP+ con comunicazione AS-i (Actuator Sensor Interface) è progettato per una automazione ottimale delle valvole di processo INOXPA.
    Download
  • E-mail
Dokument N° 802922_C-TOP+ As-i
Titel C-TOP+ with AS-interface
Dateityp .pdf
Zusammenfassung C-TOP+ con AS-interface, C-TOP+ with AS-interface, C-TOP+ avec AS-interface, C-TOP+ mit AS-Interface
    Download
  • E-mail